DFI SB630-CRM User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 183
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
30
2
Hardware Installation
These jumpers are used to select the power of the USB ports. Selecting
+5V_standby will allow you to use a USB device to wake up the system.
Important:
If you are using the Wake-On-USB Keyboard/Mouse function for 2 USB
ports, the +5V_standby power source of your power supply must sup-
port 1.5A. For 3 or more USB ports, the +5V_standby power source of
your power supply must support 2A.
USB Power Select
USB 0-1/8-9
(JP4)
2-3 On:
+5V_standby
1-2 On: +5V
(default)
2-3 On:
+5V_standby
1-2 On: +5V
(default)
132
1
3
2
3
1
2
3
1
2
USB 10-13 (JP6)
USB 2-3 (JP5)
2-3 On:
+5V_standby
1-2 On: +5V
(default)
312
3
1
2
Note:
USB 4-5 power select only support +5V.